LAPSE:2023.26881
Published Article
LAPSE:2023.26881
AATTENUATION—The Atmospheric Attenuation Model for CSP Tower Plants: A Look-Up Table for Operational Implementation
Natalie Hanrieder, Abdellatif Ghennioui, Stefan Wilbert, Manajit Sengupta, Luis F. Zarzalejo
April 3, 2023
Abstract
Attenuation of solar radiation between the receiver and the heliostat field in concentrated solar power (CSP) tower plants can reduce the overall system performance significantly. The attenuation varies strongly with time and the average attenuation at different sites might also vary strongly from each other. If no site specific attenuation data is available, the optimal plant design cannot be determined and rough estimations of the attenuation effect are required leading to high uncertainties of yield analysis calculations. The attenuation is caused mainly by water vapor content and aerosol particles in the lower atmospheric layer above ground. Although several on-site measurement systems have been developed during recent years, attenuation data sets are usually not available to be included during the plant project development. An Atmospheric Attenuation (AATTENUATION) model to derive the atmospheric transmittance between a heliostat and receiver on the basis of common direct normal irradiance (DNI), temperature, relative humidity, and barometric pressure measurements was developed and validated by the authors earlier. The model allows the accurate estimation of attenuation for sites with low attenuation and gives an estimation of the attenuation for less clear sites. However, the site-dependent coefficients of the AATTENUATION model had to be developed individually for each site of interest, which required time-consuming radiative transfer simulations, considering the exact location and altitude, as well as the pre-dominant aerosol type at the location. This strongly limited the application of the model despite its typically available input data. In this manuscript, a look-up table (LUT) is presented which enables the application of the AATTENUATION model at the site of interest without the necessity to perform the according complex radiative transfer calculations for each site individually. This enables the application of the AATTENUATION model for virtually all resource assessments for tower plants and in an operational mode in real time within plant monitoring systems around the world. The LUT also facilitates the generation of solar attenuation maps on the basis of long-term meteorological data sets which can be considered during resource assessment for CSP tower plant projects. The LUTs are provided together with this manuscript as supplementary files. The LUT for the AATTENUATION model was developed for a solar zenith angle (SZA) grid of 1°, an altitude grid of 100 m, 7 different standard aerosol types and the standard AFGL atmospheres for mid-latitudes and the tropics. The LUT was tested against the original version of the AATTENUATION model at 4 sites in Morocco and Spain, and it was found that the additional uncertainty introduced by the application of the LUT is negligible. With the information of latitude, longitude, altitude above mean sea level, DNI, relative humidity (RH), ambient temperature (Tair), and barometric pressure (bp), the attenuation can be now derived easily for each site of interest.
Keywords
atmospheric extinction, attenuation loss, central receiver, CSP, solar energy, solar resource assessment, solar tower plant, transmittance model
Suggested Citation
Hanrieder N, Ghennioui A, Wilbert S, Sengupta M, Zarzalejo LF. AATTENUATION—The Atmospheric Attenuation Model for CSP Tower Plants: A Look-Up Table for Operational Implementation. (2023). LAPSE:2023.26881
Author Affiliations
Hanrieder N: German Aerospace Center (DLR), Institute of Solar Research, Paseo de Almería 73,2, 04001 Almería, Spain
Ghennioui A: Green Energy Park (IRESEN, UM6P), Km 2 Route Régionale R206, Benguerir 43152, Morocco
Wilbert S: German Aerospace Center (DLR), Institute of Solar Research, Paseo de Almería 73,2, 04001 Almería, Spain [ORCID]
Sengupta M: National Renewable Energy Laboratory, 1617 Cole Blvd, Golden, CO 80401, USA
Zarzalejo LF: Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas (CIEMAT), División de Energías Renovables, Avda. Complutense 40, 28040 Madrid, Spain
Journal Name
Energies
Volume
13
Issue
20
Article Number
E5248
Year
2020
Publication Date
2020-10-09
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en13205248, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.26881
This Record
External Link

https://doi.org/10.3390/en13205248
Publisher Version
Download
Files
Apr 3, 2023
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
304
Version History
[v1] (Original Submission)
Apr 3, 2023
 
Verified by curator on
Apr 3, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.26881
 
Record Owner
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version