A Proposed Harmonic Monitoring System for Large Power Users Considering Harmonic Limits
March 31, 2023
Abstract
Most power utilities within Southern Africa are faced with the challenges of harmonic distortion due to the high penetration of renewable energy sources (RES) and the use of electronic devices. There is an excessive total harmonic distortion (THD) measured at the point of common coupling (PCC). In this paper, a proposed harmonic monitoring system for large power users (LPUs) is developed. This proposed system considers harmonic limits of the individual and THD of the customers allowed injecting into the network, which should be part of the contractual electricity supply agreement (ESA). Hence, it will enable the monitoring of harmonic distortion to be smooth by determining whether the customer has passed or failed compliance for individual harmonic order and the THD of the voltage. The measurements of harmonic distortion are done using the Unipower power quality (PQ) analyzers that are connected at different points within the industrial network. Measurements of harmonic distortion of an industrial site are compared to the simulation results performed by DIgSILENT software to validate the proposed harmonic monitoring system. Based on the validation results, it is recommended that the ESA between the power utilities and the customers should consist of the harmonic limits.
Most power utilities within Southern Africa are faced with the challenges of harmonic distortion due to the high penetration of renewable energy sources (RES) and the use of electronic devices. There is an excessive total harmonic distortion (THD) measured at the point of common coupling (PCC). In this paper, a proposed harmonic monitoring system for large power users (LPUs) is developed. This proposed system considers harmonic limits of the individual and THD of the customers allowed injecting into the network, which should be part of the contractual electricity supply agreement (ESA). Hence, it will enable the monitoring of harmonic distortion to be smooth by determining whether the customer has passed or failed compliance for individual harmonic order and the THD of the voltage. The measurements of harmonic distortion are done using the Unipower power quality (PQ) analyzers that are connected at different points within the industrial network. Measurements of harmonic distortion of an industrial site are compared to the simulation results performed by DIgSILENT software to validate the proposed harmonic monitoring system. Based on the validation results, it is recommended that the ESA between the power utilities and the customers should consist of the harmonic limits.
Record ID
Keywords
electricity supply agreement, harmonic distortion, harmonic limit, harmonic measurement, harmonic monitoring
Subject
Suggested Citation
Sinvula R, Abo-Al-Ez KM, Kahn MT. A Proposed Harmonic Monitoring System for Large Power Users Considering Harmonic Limits. (2023). LAPSE:2023.26134
Author Affiliations
Sinvula R: Faculty of Engineering and the Built Environment, Department of Electrical, Electronic and Computer Engineering, Cape Peninsula University of Technology, Cape Town 7535, South Africa [ORCID]
Abo-Al-Ez KM: Faculty of Engineering and the Built Environment, Department of Electrical, Electronic and Computer Engineering, Cape Peninsula University of Technology, Cape Town 7535, South Africa [ORCID]
Kahn MT: Faculty of Engineering and the Built Environment, Department of Electrical, Electronic and Computer Engineering, Cape Peninsula University of Technology, Cape Town 7535, South Africa
Abo-Al-Ez KM: Faculty of Engineering and the Built Environment, Department of Electrical, Electronic and Computer Engineering, Cape Peninsula University of Technology, Cape Town 7535, South Africa [ORCID]
Kahn MT: Faculty of Engineering and the Built Environment, Department of Electrical, Electronic and Computer Engineering, Cape Peninsula University of Technology, Cape Town 7535, South Africa
Journal Name
Energies
Volume
13
Issue
17
Article Number
E4507
Year
2020
Publication Date
2020-09-01
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en13174507, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.26134
This Record
External Link

https://doi.org/10.3390/en13174507
Publisher Version
Download
Meta
Record Statistics
Record Views
218
Version History
[v1] (Original Submission)
Mar 31, 2023
Verified by curator on
Mar 31, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.26134
Record Owner
Auto Uploader for LAPSE
Links to Related Works