Data centers (DCs) are becoming increasingly important in recent years, and highly efficient and reliable operation and management of DCs is now required. The generated heat density of the rack and information and communication technology (ICT) equipment is predicted to get higher in the future, so it is crucial to maintain the appropriate temperature environment in the server room where high heat is generated in order to ensure continuous service. It is especially important to predict changes of rack intake temperature in the server room when the computer room air conditioner (CRAC) is shut down, which can cause a rapid rise in temperature. However, it is quite difficult to predict the rack temperature accurately, which in turn makes it difficult to determine the impact on service in advance. In this research, we propose a model that predicts the rack intake temperature after the CRAC is shut down. Specifically, we use machine learning to construct a gradient boosting decision tree model with data from the CRAC, ICT equipment, and rack intake temperature. Experimental results demonstrate that the proposed method has a very high prediction accuracy: the coefficient of determination was 0.90 and the root mean square error (RMSE) was 0.54. Our model makes it possible to evaluate the impact on service and determine if action to maintain the temperature environment is required. We also clarify the effect of explanatory variables and training data of the machine learning on the model accuracy.
Keywords
continuous and reliable operation, data center, Machine Learning, server room, temperature environment, temperature prediction
Suggested Citation
Sasakura K, Aoki T, Komatsu M, Watanabe T. Rack Temperature Prediction Model Using Machine Learning after Stopping Computer Room Air Conditioner in Server Room. (2023). LAPSE:2023.25936
Author Affiliations
Sasakura K: NTT FACILITIES INC, 1-8 Shinohashi 1 Chome, Kotoku, Tokyo 135−0007, Japan
Aoki T: NTT FACILITIES INC, 1-8 Shinohashi 1 Chome, Kotoku, Tokyo 135−0007, Japan
Komatsu M: NTT FACILITIES INC, 1-8 Shinohashi 1 Chome, Kotoku, Tokyo 135−0007, Japan
Watanabe T: NTT FACILITIES INC, 1-8 Shinohashi 1 Chome, Kotoku, Tokyo 135−0007, Japan
Journal Name
Energies
Volume
13
Issue
17
Article Number
E4300
Year
2020
Publication Date
2020-08-19
Published Version
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en13174300, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.25936
This Record
External Link

doi:10.3390/en13174300
Publisher Version
Download
Files
[Download 1v1.pdf] (6.5 MB)
Mar 31, 2023
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
64
Version History
[v1] (Original Submission)
Mar 31, 2023
 
Verified by curator on
Mar 31, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.25936
 
Original Submitter
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version