Financial Analysis of the Use of Two Horizontal Drain Water Heat Recovery Units
March 29, 2023
The growing interest in the use of unconventional energy sources is a stimulus for the development of dedicated devices and technologies. Drain water heat recovery (DWHR) units can be an example of such devices. They allow the recovery of part of the heat energy deposited in grey water. This paper describes the results of research on the assessment of the financial profitability of the use of two horizontal heat exchanger solutions, taking into account the actual distribution of cold water temperature during the operating year in the plumbing and two operating regimes of the premises as the residential and service facilities. The analysis showed that the use of a horizontal heat exchanger with increased efficiency in a dwelling in a 15-year life cycle allowed for achieving more than twice as much savings (reaching up to EUR 1427) compared to a classic horizontal heat exchanger. At the same time, it was shown that the installation of this type of equipment was more profitable the greater the water consumption of the premises. The article also notes the impact of cold water temperature in the installation on the results of the analysis. It was featured that taking temperature on the basis of installation design recommendations led to significant distortions in the financial analysis. On the other hand, comparing the method of averaging the cold water temperature (daily, monthly and yearly), it was determined that averaging the temperature over the annual cycle was an acceptable simplification of the model. The research results presented in the paper have a practical aspect and may constitute guidelines for designers and potential investors. In addition, they can be an incentive to continue research on heat exchangers by other scientific centers, which on a global scale will increase the universality of their use.
Keywords
drain water heat recovery (DWHR) unit, financial analysis, net present value (NPV), waste heat recovery
Suggested Citation
Pochwat K, Kordana-Obuch S, Starzec M, Piotrowska B. Financial Analysis of the Use of Two Horizontal Drain Water Heat Recovery Units. (2023). LAPSE:2023.25751
Author Affiliations
Pochwat K: Department of Infrastructure and Water Management, Rzeszow University of Technology, al. Powstańców Warszawy 12, 35-959 Rzeszów, Poland [ORCID]
Kordana-Obuch S: Department of Infrastructure and Water Management, Rzeszow University of Technology, al. Powstańców Warszawy 12, 35-959 Rzeszów, Poland [ORCID]
Starzec M: Department of Infrastructure and Water Management, Rzeszow University of Technology, al. Powstańców Warszawy 12, 35-959 Rzeszów, Poland [ORCID]
Piotrowska B: Department of Infrastructure and Water Management, Rzeszow University of Technology, al. Powstańców Warszawy 12, 35-959 Rzeszów, Poland [ORCID]
Journal Name
Energies
Volume
13
Issue
16
Article Number
E4113
Year
2020
Publication Date
2020-08-09
Published Version
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en13164113, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.25751
This Record
External Link

doi:10.3390/en13164113
Publisher Version
Download
Files
[Download 1v1.pdf] (3.9 MB)
Mar 29, 2023
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
66
Version History
[v1] (Original Submission)
Mar 29, 2023
 
Verified by curator on
Mar 29, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.25751
 
Original Submitter
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version