LAPSE:2023.21873
Published Article
LAPSE:2023.21873
CFD Analysis on the Heat Transfer and Fluid Flow of Solar Air Heater having Transverse Triangular Block at the Bottom of Air Duct
Hwi-Ung Choi, Kwang-Hwan Choi
March 23, 2023
In this study, a two-dimensional CFD (computational fluid dynamics) analysis was performed to investigate the heat-transfer and fluid-friction characteristics in a solar air heater having a transverse triangular block at the bottom of the air duct. The Reynolds number, block height (e), pitch (P), and length (l) were chosen as design parameters. The results are validated by comparing the Nusselt number predicted by simulation with available experimental results. Renormalization-group (RNG) k - ε model with enhanced wall-treatment was selected as the most appropriate turbulence model. From the results, it was found that the presence of a transverse triangular block produces a higher Nusselt number than that of smooth air duct. The enhancement in Nusselt number varied from 1.19 to 3.37, according to the geometric conditions investigated. However, the use of transverse triangular block also results in significantly higher friction losses. The thermohydraulic performance (THPP) was also estimated and has a maximum value of 1.001 for height (e) of 20 mm, length (l) of 120 mm, and pitch (P) of 150 mm, at Reynolds number of 8000. Furthermore, in the present study, correlations of the Nusselt number and friction factor were developed as a function of geometrical conditions of the transverse triangular block and Reynolds number, which can be used to predict the value of Nusselt number and friction factor with the absolute percentage deviations of 3.29% and 7.92%, respectively.
Keywords
Computational Fluid Dynamics, friction factor, Nusselt number, solar air heater, solar collector
Suggested Citation
Choi HU, Choi KH. CFD Analysis on the Heat Transfer and Fluid Flow of Solar Air Heater having Transverse Triangular Block at the Bottom of Air Duct. (2023). LAPSE:2023.21873
Author Affiliations
Choi HU: Department of Refrigeration and Air-Conditioning Engineering, Pukyong National University, Busan 48513, Korea [ORCID]
Choi KH: Department of Refrigeration and Air-Conditioning Engineering, Pukyong National University, Busan 48513, Korea
Journal Name
Energies
Volume
13
Issue
5
Article Number
E1099
Year
2020
Publication Date
2020-03-02
Published Version
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en13051099, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.21873
This Record
External Link

doi:10.3390/en13051099
Publisher Version
Download
Files
[Download 1v1.pdf] (6.5 MB)
Mar 23, 2023
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
62
Version History
[v1] (Original Submission)
Mar 23, 2023
 
Verified by curator on
Mar 23, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.21873
 
Original Submitter
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version