LAPSE:2023.17630
Published Article

LAPSE:2023.17630
Numerical Simulation of the Effects of Oil Gun Location and Oil Feed Rate on Coal Ignition and Burner Wall Temperature in a Tiny Oil Ignition Burner
March 6, 2023
Abstract
To solve the overheating problem of tiny oil ignition burners’ walls during the firing-up process in a 330 MWe tangentially pulverized coal-fired boiler, a numerical model of a tiny oil ignition burner was carefully built considering combustion, gas−solid flow, and heat transfer. Then, the burner location and oil feed rate were optimized based on the model to prevent the burner’s walls from overheating. The effects of the oil gun extension distance (100, 200, 300, 400, 500 mm) and oil feed rate (160, 140, 120, 100, 80, 70, 60 kg/h) on coal ignition performance and burner wall temperature were carefully investigated. The simulation results showed good agreement with the measured results. The results indicated that decreasing the oil gun distance within the burner diminished the flame length of the co-combustion of oil and pulverized coal, thus lowering the burner wall temperature. Decreasing the oil feed rate appropriately could also reduce the burner wall temperature without influencing the ignition performance. Considering both ignition performance and burner wall temperature, an extension of 400 mm of the oil gun location and an oil feed rate of 160 kg/h were successfully applied to the actual operation without adverse effects. Moreover, it is suggested to move the temperature monitor points from the burner upper wall to the burner side wall.
To solve the overheating problem of tiny oil ignition burners’ walls during the firing-up process in a 330 MWe tangentially pulverized coal-fired boiler, a numerical model of a tiny oil ignition burner was carefully built considering combustion, gas−solid flow, and heat transfer. Then, the burner location and oil feed rate were optimized based on the model to prevent the burner’s walls from overheating. The effects of the oil gun extension distance (100, 200, 300, 400, 500 mm) and oil feed rate (160, 140, 120, 100, 80, 70, 60 kg/h) on coal ignition performance and burner wall temperature were carefully investigated. The simulation results showed good agreement with the measured results. The results indicated that decreasing the oil gun distance within the burner diminished the flame length of the co-combustion of oil and pulverized coal, thus lowering the burner wall temperature. Decreasing the oil feed rate appropriately could also reduce the burner wall temperature without influencing the ignition performance. Considering both ignition performance and burner wall temperature, an extension of 400 mm of the oil gun location and an oil feed rate of 160 kg/h were successfully applied to the actual operation without adverse effects. Moreover, it is suggested to move the temperature monitor points from the burner upper wall to the burner side wall.
Record ID
Keywords
extension distance, oil feed rate, Simulation, tiny oil ignition burner, wall overheating
Subject
Suggested Citation
Ma Q, Zhong W, Chen X, Li J, Zhang H. Numerical Simulation of the Effects of Oil Gun Location and Oil Feed Rate on Coal Ignition and Burner Wall Temperature in a Tiny Oil Ignition Burner. (2023). LAPSE:2023.17630
Author Affiliations
Ma Q: Key Laboratory of Energy Thermal Conversion and Control of Ministry of Education, School of Energy and Environment, Southeast University, Nanjing 210096, China; China Datang Corporation Science and Technology Research Institute, Beijing 100040, China
Zhong W: Key Laboratory of Energy Thermal Conversion and Control of Ministry of Education, School of Energy and Environment, Southeast University, Nanjing 210096, China
Chen X: Key Laboratory of Energy Thermal Conversion and Control of Ministry of Education, School of Energy and Environment, Southeast University, Nanjing 210096, China
Li J: China Datang Corporation Science and Technology Research Institute, Beijing 100040, China
Zhang H: China Datang Corporation Science and Technology Research Institute, Beijing 100040, China
Zhong W: Key Laboratory of Energy Thermal Conversion and Control of Ministry of Education, School of Energy and Environment, Southeast University, Nanjing 210096, China
Chen X: Key Laboratory of Energy Thermal Conversion and Control of Ministry of Education, School of Energy and Environment, Southeast University, Nanjing 210096, China
Li J: China Datang Corporation Science and Technology Research Institute, Beijing 100040, China
Zhang H: China Datang Corporation Science and Technology Research Institute, Beijing 100040, China
Journal Name
Energies
Volume
14
Issue
22
First Page
7597
Year
2021
Publication Date
2021-11-13
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en14227597, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.17630
This Record
External Link

https://doi.org/10.3390/en14227597
Publisher Version
Download
Meta
Record Statistics
Record Views
218
Version History
[v1] (Original Submission)
Mar 6, 2023
Verified by curator on
Mar 6, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.17630
Record Owner
Auto Uploader for LAPSE
Links to Related Works