LAPSE:2023.7211
Published Article

LAPSE:2023.7211
Energy, Exergy Efficiency and Thermal-Electrical Production Assessment for an Active Water Heating System Using Four PV/T Module Models
February 24, 2023
Abstract
In order to objectively reflect the energy utilization performance of an active water heating system (AWHS) using photovoltaic/thermal (PV/T) modules, this study proposes a new evaluation method based on energy efficiency, exergy efficiency and thermal-electrical output of a system in year-round weather conditions. Four samples of PV/T modules were surveyed to compare and evaluate the effectiveness of the system, called MD1, MD2, MD3 and MD4, respectively. The simulation program was developed to suit four types of PV/T modules and MATLAB was used as the programming language. The water flow through the four PV/T module samples and the hot water tank volume were investigated for the highest exergy efficiency of the system. The final results illustrate that in the weather conditions of Ho Chi Minh City, Vietnam, the system has the highest energy efficiency, exergy efficiency and thermal output when using MD1 with 57.85%, 15.67% and 2.93 kWh/m2/day, respectively, while the system has highest electrical output when using MD3 with 0.8 kWh/m2/day. In addition, under stable conditions ignoring heat loss, MD1 has the highest thermal efficiency with 54.85% and MD3 type has the highest electrical efficiency with 13.67%.
In order to objectively reflect the energy utilization performance of an active water heating system (AWHS) using photovoltaic/thermal (PV/T) modules, this study proposes a new evaluation method based on energy efficiency, exergy efficiency and thermal-electrical output of a system in year-round weather conditions. Four samples of PV/T modules were surveyed to compare and evaluate the effectiveness of the system, called MD1, MD2, MD3 and MD4, respectively. The simulation program was developed to suit four types of PV/T modules and MATLAB was used as the programming language. The water flow through the four PV/T module samples and the hot water tank volume were investigated for the highest exergy efficiency of the system. The final results illustrate that in the weather conditions of Ho Chi Minh City, Vietnam, the system has the highest energy efficiency, exergy efficiency and thermal output when using MD1 with 57.85%, 15.67% and 2.93 kWh/m2/day, respectively, while the system has highest electrical output when using MD3 with 0.8 kWh/m2/day. In addition, under stable conditions ignoring heat loss, MD1 has the highest thermal efficiency with 54.85% and MD3 type has the highest electrical efficiency with 13.67%.
Record ID
Keywords
active water heating system, Energy Efficiency, Exergy Efficiency, heat-electricity output, numerical simulation, photovoltaic/thermal (PV/T) module
Subject
Suggested Citation
Hoang VV, Le HC, Nguyen BT. Energy, Exergy Efficiency and Thermal-Electrical Production Assessment for an Active Water Heating System Using Four PV/T Module Models. (2023). LAPSE:2023.7211
Author Affiliations
Hoang VV: Department of Heat and Refrigeration Engineering, Faculty of Mechanical Engineering, Ho Chi Minh City University of Technology (HCMUT), 268 Ly Thuong Kiet Street, District 10, Ho Chi Minh City 700000, Vietnam; Vietnam National University Ho Chi Minh City, [ORCID]
Le HC: Department of Heat and Refrigeration Engineering, Faculty of Mechanical Engineering, Ho Chi Minh City University of Technology (HCMUT), 268 Ly Thuong Kiet Street, District 10, Ho Chi Minh City 700000, Vietnam; Vietnam National University Ho Chi Minh City,
Nguyen BT: Department of Heat and Refrigeration Engineering, Faculty of Mechanical Engineering, Ho Chi Minh City University of Technology (HCMUT), 268 Ly Thuong Kiet Street, District 10, Ho Chi Minh City 700000, Vietnam; Vietnam National University Ho Chi Minh City, [ORCID]
Le HC: Department of Heat and Refrigeration Engineering, Faculty of Mechanical Engineering, Ho Chi Minh City University of Technology (HCMUT), 268 Ly Thuong Kiet Street, District 10, Ho Chi Minh City 700000, Vietnam; Vietnam National University Ho Chi Minh City,
Nguyen BT: Department of Heat and Refrigeration Engineering, Faculty of Mechanical Engineering, Ho Chi Minh City University of Technology (HCMUT), 268 Ly Thuong Kiet Street, District 10, Ho Chi Minh City 700000, Vietnam; Vietnam National University Ho Chi Minh City, [ORCID]
Journal Name
Energies
Volume
15
Issue
24
First Page
9634
Year
2022
Publication Date
2022-12-19
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en15249634, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.7211
This Record
External Link

https://doi.org/10.3390/en15249634
Publisher Version
Download
Meta
Record Statistics
Record Views
694
Version History
[v1] (Original Submission)
Feb 24, 2023
Verified by curator on
Feb 24, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
http://psecommunity.org/LAPSE:2023.7211
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.08 seconds)
[0.09 s]
