LAPSE:2023.26791
Published Article

LAPSE:2023.26791
Effects of Nozzle Exit Position on Condenser Outlet Split Ejector-Based R600a Household Refrigeration Cycle
April 3, 2023
Abstract
The objective of this study is to investigate the performance characteristics of a small-sized R600a household refrigeration system that adopts a condenser outlet split (COS) ejector cycle under various operating and ejector geometry conditions. The coefficient of performance and pressure lifting ratio of the COS ejector cycle were analyzed and measured by varying the entrainment ratio, compressor speed, and nozzle exit position. The optimum nozzle exit position in the COS ejector cycle adopted to achieve the maximum cycle performance was proposed as a function of the compressor speed and entrainment ratio. The optimum nozzle exit position was 0 mm when the entrainment ratio and compressor speed were low, and it increased as the entrainment ratio and compressor speed increased owing to the associated internal pressure drop in the suction section.
The objective of this study is to investigate the performance characteristics of a small-sized R600a household refrigeration system that adopts a condenser outlet split (COS) ejector cycle under various operating and ejector geometry conditions. The coefficient of performance and pressure lifting ratio of the COS ejector cycle were analyzed and measured by varying the entrainment ratio, compressor speed, and nozzle exit position. The optimum nozzle exit position in the COS ejector cycle adopted to achieve the maximum cycle performance was proposed as a function of the compressor speed and entrainment ratio. The optimum nozzle exit position was 0 mm when the entrainment ratio and compressor speed were low, and it increased as the entrainment ratio and compressor speed increased owing to the associated internal pressure drop in the suction section.
Record ID
Keywords
condenser outlet split, household refrigeration cycle, nozzle exit position, Optimization, two-phase ejector
Subject
Suggested Citation
Jeon Y, Kim H, Ahn JH, Kim S. Effects of Nozzle Exit Position on Condenser Outlet Split Ejector-Based R600a Household Refrigeration Cycle. (2023). LAPSE:2023.26791
Author Affiliations
Jeon Y: Department of Refrigeration and Air-Conditioning Engineering, Chonnam National University, 50 Daehak-ro, Yeosu, Chonnam 59626, Korea
Kim H: Research Group of Consumer Safety, Korea Food Research Institute, 245 Nongsaengmyeong-ro, Iseo-Myeon, Wanju-Gun, Jeollabuk-do 55365, Korea [ORCID]
Ahn JH: Research Group of Consumer Safety, Korea Food Research Institute, 245 Nongsaengmyeong-ro, Iseo-Myeon, Wanju-Gun, Jeollabuk-do 55365, Korea
Kim S: Department of Mechanical Design Engineering, Chonnam National University, 50 Daehak-ro, Yeosu, Chonnam 59626, Korea
Kim H: Research Group of Consumer Safety, Korea Food Research Institute, 245 Nongsaengmyeong-ro, Iseo-Myeon, Wanju-Gun, Jeollabuk-do 55365, Korea [ORCID]
Ahn JH: Research Group of Consumer Safety, Korea Food Research Institute, 245 Nongsaengmyeong-ro, Iseo-Myeon, Wanju-Gun, Jeollabuk-do 55365, Korea
Kim S: Department of Mechanical Design Engineering, Chonnam National University, 50 Daehak-ro, Yeosu, Chonnam 59626, Korea
Journal Name
Energies
Volume
13
Issue
19
Article Number
E5160
Year
2020
Publication Date
2020-10-03
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en13195160, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.26791
This Record
External Link

https://doi.org/10.3390/en13195160
Publisher Version
Download
Meta
Record Statistics
Record Views
329
Version History
[v1] (Original Submission)
Apr 3, 2023
Verified by curator on
Apr 3, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
http://psecommunity.org/LAPSE:2023.26791
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.08 seconds)
[0.08 s]
