Comparison among Methods for Induction Motor Low-Intrusive Efficiency Evaluation Including a New AGT Approach with a Modified Stator Resistance
Camila Paes Salomon, Wilson Cesar Sant’Ana, Germano Lambert-Torres, Luiz Eduardo Borges da Silva, Erik Leandro Bonaldi, Levy Ely de Lacerda de Oliveira
June 23, 2020
Induction motors consume a great portion of the generated electrical energy. Moreover, most of them work at underloaded conditions, so they have low efficiencies and waste a lot of energy. Because of this, the efficiency estimation of in-service induction motors is a matter of great importance. This efficiency estimation is usually performed through indirect methods, which do not require invasive measurements of torque or speed. One of these methods is the modified Air-Gap Torque (AGT) method, which only requires voltage and current data, the stator resistance value, and the mechanical losses. This paper approaches the computation of a modified stator resistance including the mechanical losses effect to be applied in the AGT method for torque and efficiency estimation of induction motors. Some improvements are proposed in the computation of this resistance by using a direct method, as well as the possibility to estimate this parameter directly from the nameplate data of the induction motor. The proposed methodology only relies on line voltages, currents, and nameplate data and is not intrusive. The proposed methodology is analyzed through simulation and validated through experimental results with three-phase induction motors. Also, a comparison of methods for in-service induction motors efficiency estimation is presented for the tested motors.
Keywords
air-gap torque, condition monitoring, efficiency estimation, induction motors, stator resistance
Suggested Citation
Salomon CP, Sant’Ana WC, Lambert-Torres G, Borges da Silva LE, Bonaldi EL, de Oliveira LEDL. Comparison among Methods for Induction Motor Low-Intrusive Efficiency Evaluation Including a New AGT Approach with a Modified Stator Resistance. (2020). LAPSE:2020.0652
Author Affiliations
Salomon CP: Gnarus Institute, Itajuba 37500-052, Brazil [ORCID]
Sant’Ana WC: Gnarus Institute, Itajuba 37500-052, Brazil; Institute of System Engineering and Information Technology, Itajuba Federal University, Itajuba37500-903, Brazil
Lambert-Torres G: Gnarus Institute, Itajuba 37500-052, Brazil [ORCID]
Borges da Silva LE: Institute of System Engineering and Information Technology, Itajuba Federal University, Itajuba37500-903, Brazil
Bonaldi EL: Gnarus Institute, Itajuba 37500-052, Brazil
de Oliveira LEDL: Gnarus Institute, Itajuba 37500-052, Brazil [ORCID]
[Login] to see author email addresses.
Journal Name
Energies
Volume
11
Issue
4
Article Number
E691
Year
2018
Publication Date
2018-03-21
Published Version
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en11040691, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2020.0652
This Record
External Link

doi:10.3390/en11040691
Publisher Version
Download
Files
[Download 1v1.pdf] (5.2 MB)
Jun 23, 2020
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
389
Version History
[v1] (Original Submission)
Jun 23, 2020
 
Verified by curator on
Jun 23, 2020
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2020.0652
 
Original Submitter
Calvin Tsay
Links to Related Works
Directly Related to This Work
Publisher Version