The switched inertance hydraulic converter (SIHC) is a new technology providing an alternative to conventional proportional or servo-valve-controlled systems in the area of fluid power. SIHCs can adjust or control flow and pressure by means of using digital control signals that do not rely on throttling the flow and dissipation of power, and provide hydraulic systems with high-energy efficiency, flexible control, and insensitivity to contamination. In this article, the analytical models of an SIHC in a three-port flow-booster configuration were used and validated at high operating pressure, with the low- and high-pressure supplies of 30 and 90 bar and a high delivery flow rate of 21 L/min. The system dynamics, flow responses, and power consumption were investigated and theoretically and experimentally validated. Results were compared to previous results achieved using low operating pressures, where low- and high-pressure supplies were 20 and 30 bar, and the delivery flow rate was 7 L/min. We concluded that the analytical models could effectively predict SIHC performance, and higher operating pressures and flow rates could result in system uncertainties that need to be understood well. As high operating pressure or flow rate is a common requirement in hydraulic systems, this constitutes an important contribution to the development of newly switched inertance hydraulic converters and the improvement of fluid-power energy efficiency.
Keywords
digital hydraulics, efficient fluid power, flow booster, high-speed switching valves, pressure booster, switched inertance hydraulic systems
Suggested Citation
Yuan C, Mao Lung VL, Plummer A, Pan M. Theoretical and Experimental Studies of a Digital Flow Booster Operating at High Pressures and Flow Rates. (2020). LAPSE:2020.0357
Author Affiliations
Yuan C: Centre for Power Transmission and Motion Control, Department of Mechanical Engineering, University of Bath, Claverton Down BA2 7AY, UK
Mao Lung VL: Centre for Power Transmission and Motion Control, Department of Mechanical Engineering, University of Bath, Claverton Down BA2 7AY, UK
Plummer A: Centre for Power Transmission and Motion Control, Department of Mechanical Engineering, University of Bath, Claverton Down BA2 7AY, UK
Pan M: Centre for Power Transmission and Motion Control, Department of Mechanical Engineering, University of Bath, Claverton Down BA2 7AY, UK
Journal Name
Processes
Volume
8
Issue
2
Article Number
E211
Year
2020
Publication Date
2020-02-10
Published Version
ISSN
2227-9717
Version Comments
Original Submission
Other Meta
PII: pr8020211, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2020.0357
This Record
External Link

doi:10.3390/pr8020211
Publisher Version
Download
Files
[Download 1v1.pdf] (2.4 MB)
Apr 14, 2020
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
436
Version History
[v1] (Original Submission)
Apr 14, 2020
 
Verified by curator on
Apr 14, 2020
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2020.0357
 
Original Submitter
Calvin Tsay
Links to Related Works
Directly Related to This Work
Publisher Version