Demand Response (DR) programs under the umbrella of Demand Side Management (DSM) tend to involve end users in optimizing their Power Consumption (PC) patterns and offer financial incentives to shift the load at “low-priced” hours. However, users have their own preferences of anticipating the amount of consumed electricity. While installing an Energy Management System (EMS), the user must be assured that this investment gives optimum comfort of bill savings, as well as appliance utility considering Time of Use (ToU). Moreover, there is a difference between desired load distribution and optimally-scheduled load across a 24-h time frame for lowering electricity bills. This difference in load usage timings, if it is beyond the tolerance level of a user, increases frustration. The comfort level is a highly variable phenomenon. An EMS giving optimum comfort to one user may not be able to provide the same level of satisfaction to another who has different preferences regarding electricity bill savings or appliance utility. Under such a diversity of human behaviors, it is difficult to select an EMS for an individual user. In this work, a numeric performance metric,“User Comfort Level (UCL)”isformulatedonthebasisofuserpreferencesoncostsaving,toleranceindelayregardinguse of an appliance and return of investment. The proposed framework (UCL) allows the user to select an EMS optimally that suits his.her preferences well by anticipating electricity bill reduction, tolerable delay in ToU of the appliance and return on investment. Furthermore, an extended literature analysis is conducted demonstrating generic strategies of EMSs. Five major building blocks are discussed and a comparative analysis is presented on the basis of the proposed performance metric.
Keywords
appliance utility, BPSO, DR programs, DSM, EMS, energy efficiency gap, Scheduling, user comfort
Suggested Citation
Mahmood D, Javaid N, Ahmed S, Ahmed I, Niaz IA, Abdul W, Ghouzali S. Orchestrating an Effective Formulation to Investigate the Impact of EMSs (Energy Management Systems) for Residential Units Prior to Installation. (2019). LAPSE:2019.1399
Author Affiliations
Mahmood D: COMSATS Institute of Information Technology, Islamabad 44000, Pakistan
Javaid N: COMSATS Institute of Information Technology, Islamabad 44000, Pakistan [ORCID]
Ahmed S: COMSATS Institute of Information Technology, Islamabad 44000, Pakistan; Institute of Management Sciences (IMS), Peshawar 25000, Pakistan [ORCID]
Ahmed I: Institute of Management Sciences (IMS), Peshawar 25000, Pakistan [ORCID]
Niaz IA: COMSATS Institute of Information Technology, Islamabad 44000, Pakistan [ORCID]
Abdul W: Department of Computer Engineering, College of Computer and Information Sciences, King Saud University, Riyadh 11633, Saudi Arabia [ORCID]
Ghouzali S: Information Technology Department, College of Computer and Information Sciences, King Saud University, Riyadh 11633, Saudi Arabia
[Login] to see author email addresses.
Journal Name
Energies
Volume
10
Issue
3
Article Number
E335
Year
2017
Publication Date
2017-03-09
Published Version
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en10030335, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2019.1399
This Record
External Link

doi:10.3390/en10030335
Publisher Version
Download
Files
[Download 1v1.pdf] (1.2 MB)
Dec 10, 2019
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
490
Version History
[v1] (Original Submission)
Dec 10, 2019
 
Verified by curator on
Dec 10, 2019
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2019.1399
 
Original Submitter
Calvin Tsay
Links to Related Works
Directly Related to This Work
Publisher Version