LAPSE:2018.1084
Published Article
LAPSE:2018.1084
A Wavelet-Based Unified Power Quality Conditioner to Eliminate Wind Turbine Non-Ideality Consequences on Grid-Connected Photovoltaic Systems
Bijan Rahmani, Weixing Li, Guihua Liu
November 28, 2018
The integration of renewable power sources with power grids presents many challenges, such as synchronization with the grid, power quality problems and so on. The shunt active power filter (SAPF) can be a solution to address the issue while suppressing the grid-end current harmonics and distortions. Nonetheless, available SAPFs work somewhat unpredictably in practice. This is attributed to the dependency of the SAPF controller on nonlinear complicated equations and two distorted variables, such as load current and voltage, to produce the current reference. This condition will worsen when the plant includes wind turbines which inherently produce 3rd, 5th, 7th and 11th voltage harmonics. Moreover, the inability of the typical phase locked loop (PLL) used to synchronize the SAPF reference with the power grid also disrupts SAPF operation. This paper proposes an improved synchronous reference frame (SRF) which is equipped with a wavelet-based PLL to control the SAPF, using one variable such as load current. Firstly the fundamental positive sequence of the source voltage, obtained using a wavelet, is used as the input signal of the PLL through an orthogonal signal generator process. Then, the generated orthogonal signals are applied through the SRF-based compensation algorithm to synchronize the SAPF’s reference with power grid. To further force the remained uncompensated grid current harmonics to pass through the SAPF, an improved series filter (SF) equipped with a current harmonic suppression loop is proposed. Concurrent operation of the improved SAPF and SF is coordinated through a unified power quality conditioner (UPQC). The DC-link capacitor of the proposed UPQC, used to interconnect a photovoltaic (PV) system to the power grid, is regulated by an adaptive controller. Matlab/Simulink results confirm that the proposed wavelet-based UPQC results in purely sinusoidal grid-end currents with total harmonic distortion (THD) = 1.29%, which leads to high electrical efficiency of a grid-connected PV system.
Keywords
active series filter (SF), advanced generalized theory of instantaneous power (A-GTIP) theory, DC-link, load-terminal voltage, low–pass filter (LPF), phase locked loop (PLL), source current, synchronous reference frame (SRF) theory, unified power quality conditioner (UPQC), wavelet
Suggested Citation
Rahmani B, Li W, Liu G. A Wavelet-Based Unified Power Quality Conditioner to Eliminate Wind Turbine Non-Ideality Consequences on Grid-Connected Photovoltaic Systems. (2018). LAPSE:2018.1084
Author Affiliations
Rahmani B: Department of Electrical Engineering, Harbin Institute of Technology, Harbin 150001, China [ORCID]
Li W: Department of Electrical Engineering, Harbin Institute of Technology, Harbin 150001, China
Liu G: Department of Electrical Engineering, Harbin Institute of Technology, Harbin 150001, China
[Login] to see author email addresses.
Journal Name
Energies
Volume
9
Issue
6
Article Number
E390
Year
2016
Publication Date
2016-05-24
Published Version
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en9060390, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2018.1084
This Record
External Link

doi:10.3390/en9060390
Publisher Version
Download
Files
[Download 1v1.pdf] (6.5 MB)
Nov 28, 2018
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
583
Version History
[v1] (Original Submission)
Nov 28, 2018
 
Verified by curator on
Nov 28, 2018
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2018.1084
 
Original Submitter
Calvin Tsay
Links to Related Works
Directly Related to This Work
Publisher Version